LogTag HASO-8 is a disposable humidity and temperature data logger designed to monitor environmental conditions during the transport and storage of sensitive goods such as food, pharmaceuticals, vaccines, and medical devices.
| Product Model | HASO-8 |
| Sensor Measurement Range | -40°C to +85°C (-40°F to +185°F) |
| Operating Temperature Range | -40°C to +85°C (-40°F to +185°F) |
| Storage Temperature Range | +10°C to +50°C (+50°F to +122°F) |
| Humidity Measurement Range | 0% RH to 100% RH (non-condensing), with limitations |
| Humidity Operating Range | 0% RH to 100% RH (non-condensing), with limitations |
| Storage Humidity Range | 20% RH to 65% RH |
| Rated Temperature Reading Accuracy | Better than ±0.45°C (±0.8°F) for +0°C to +50°C (+32°F to +122°F), typically ±0.3°C (0.6°F). Better than ±0.8°C (±1.4°F) for +50°C to +80°C (+122°F to +176°F), typically ±0.5°C (0.9°F). Better than ±0.95°C (±1.7°F) for -40°C to +0°C (-40°F to +32°F), typically ±0.6°C (1.1°F). Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration. |
| Rated Humidity Reading Accuracy | Better than ±5%RH for 10%RH to 80%RH. Better than ±6%RH for 0%RH to 10%RH. Better than ±7%RH for 80%RH to 100%RH. Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration. |
| Humidity Resolution | Better than 0.1% RH. |
| Temperature Resolution | Better than 0.1°C or 0.1°F |
| Recording Capacity | 8,003 pairs of humidity and temperature readings. 53 days @ 10min logging, 80 days @ 15min logging. |
| Sampling Interval | Sampling Interval |
| Logging Start Options | Logging Start Options |
| Recording Indication | Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator. |
| Download Time | Typically less than 10 seconds for full memory, depending on computer or readout device used. |
| Environmental | IP61 (when hung or mounted vertically). |
| Power Source | CR2032 3V LiMnO2 (Fixed) |
| Battery Life | 2 years storage, followed by 6 months of operation life. |
| Real Time Clock | Built-in real time clock. Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C). |
| Connection Interface | Interface Cradle. |
| Software | LogTag® Analyzer. |
| Size | 86mm(H) x 54.5mm(W) x 8.6mm(T). |
| Weight | 34g. |
| Case Material | Polycarbonate. |
Instructions for Using the HASO-8 Device | |
English Version | VietNamese Version |