The LogTag TRED30-16 is a temperature data logger with an external probe and LCD display, enabling efficient temperature monitoring in cold chain applications. The device features audible and visual alarms, is easy to use, and is suitable for monitoring vaccines, food, and pharmaceuticals.
| Product Model | TRED30-16CP (Replaceable Battery) |
| External Sensor Measurement Range | -40 °C to +99 °C (-40 °F to +210 °F) |
| Operating Temperature Range | -30 °C to +60 °C (-22 °F to +140 °F) |
| Storage Temperature Range | -10 °C to +40 °C (+14 °F to +104 °F) |
| Rated Temperature Reading Accuracy | Better than ±0.5 °C (±0.9 °F) for -20 °C to +40 °C (-4 °F to +104 °F), typically ±0.3 °C (0.6 °F) Better than ±0.8 °C (±1.4 °F) for -40 °C to -20 °C (-40 °F to -4 °F), typically ±0.5 °C (0.9 °F) Better than ±0.8 °C (±1.4 °F) for +40 °C to +70 °C (+104 °F to +158 °F), typically ±0.7 °C (1.3 °F) Better than ±1.2 °C (±2.2 °F) for +70 °C to +99 °C (+158 °F to +210 °F), typically ±1 °C (1.8 °F) Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration When used with the CP110 Smart Probe refer to CP110 data sheet for accuracy reading |
| Rated Temperature Reading Resolution | 0.1 °C (0.2 °F) for measurements -40 °C to +50 °C (-40 °F to +122 °F) 0.2 °C (0.4 °F) for measurements +50 °C to +70 °C (+122 °F to +158 °F) 0.3 °C (0.5 °F) for measurements +70 °C to +80 °C (+158 °F to +176 °F) 0.4 °C to 0.6 °C (0.7 °F to 1 °F) for measurements +80 °C to +99 °C (+176 °F to +210 °F) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
| Sensor Reaction Time | Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types. |
| Recording Capacity | 15,905 temperature readings. 66 days @ 6 minute logging. Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics. |
| Sampling Interval | Configurable from 30 seconds to hourly |
| Logging Start Options | Push button start or specific date and time. Optional start delay of up to 18 hours |
| Recording Indication | State indicator “REC” |
| Download Time | Typically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used |
| Environmental | IP61 (when vertically mounted or hung) |
| Power Source | 3V CR2032 LiMnO2 coin cell battery, user replaceable |
| Battery Life | 1 year storage, followed by 1 year of operation with normal use (6 minute logging, statistics reviewed on the display no more than once daily for no longer than 30 seconds each time, download data monthly) NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible. |
| Real Time Clock | Built-in real time clock Rated accuracy ±25ppm @ 25 °C (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006ppm/°C (i.e typically +/- 0.00294 seconds/day/°C) |
| Standard External Sensor Cable Lengths | Standard: 1.5m (4’11″) Extended: 3m (9’10″) (Recommended maximum) |
| External Sensor Cable Type | PTFE (FDA food contact rated), coaxial |
| Size | 93mm(H) x 54.5mm(W) x 8.6mm(T) |
| Weight | 43g without external probe |
| Case Material | Polycarbonate |
USER MANUAL FOR TRED30-16 | |
English Version | VietNamese Version |